1. Product Features• With a separate
power supply design, the measurement circuit and display circuit of the product
itself do not consume the energy of the power supply under test, and the measurement
is more accurate and reliable.• LCD display, which
can display load input voltage, input current, input power, discharge time,
discharge maH, product temperature and other information.• Complete protection
mechanism with undervoltage protection, overvoltage protection, overcurrent
protection, overpower protection and overtemperature protection.• The current
adjustment uses a long-handle potentiometer, which can be rotated by hand
without the need for additional tools such as a screwdriver.• With voltage and
current correction function to meet the high precision requirements of
customers.• Parameters can be
stored off power.•Apply to various
power sources (product power, charger, charging treasure, etc.) aging or
functional test, test various battery capacity discharge characteristics,
desktop small load.2. Product illustration
3. Product details3.1 Detailed functions 1,
LCD display In
normal mode, the LCD displays the load input voltage and load temperature up;
the downstream shows the load current, power, capacity, and discharge time. In
protected mode, the LCD displays the protection code. In
the setting mode, the LCD displays various setting parameter codes and
parameter thresholds. 2,
load current regulation The
magnitude of the discharge current can be adjusted by a potentiometer. 3,
sound and light alarm When
the load is turned on, the RUN indicator is always on and the buzzer is not
ringing. When the load is off, the RUN indicator is off and the buzzer is not
ringing. After entering the protection mode, the buzzer will drop the alarm and
the RUN indicator will flash. 4,
intelligent fan cooling The
fan automatically starts when the load discharge power is greater than 10W or
the load temperature is greater than 40°C. 5,
discharge capacity and discharge time automatic statistics, as long as the load
is turned on (RUN indicator is always on) to start statistics, turn off the
load (RUN indicator is not lit), stop statistics, statistics support power-down
storage, clear statistics only one The method is to press the '-''' button when
the LCD displays the discharge capacity or discharge time. Please clear the
statistics before starting the statistics. The maximum discharge capacity (OAH)
and maximum discharge time (OHP) can be set to on or off in the setup mode, and
the threshold size can be set. When the threshold is exceeded, the load is
automatically turned off, enabling unattended discharge experiments. 6.
Perfect software and hardware protection mechanism, and the software protection
threshold can be adjusted. After software protection, the output is turned off. Hardware
protection: Both
the module power port and the load input port have anti-reverse protection. Software
protection: OVP
- Overvoltage protection (default 25.5V, can be set by yourself, after
overvoltage protection, RUN indicator flashes, LCD interface displays OVP); OCP-overcurrent
protection (default 4.10A/5.10A, can be set by yourself, after overcurrent
protection, RUN indicator flashes, LCD displays OCP); OPP-
over power protection (default 25.5W/35.5W, can be set by itself, after over
power protection, RUN indicator flashes, LCD flashes OPP); OTP
- Over temperature protection (over temperature protection after load
temperature is greater than 80 °C, RUN indicator flashes, LCD displays OTP); LVP
- undervoltage protection (default 1.5V, can be set by yourself, after
undervoltage protection, RUN indicator flashes, liquid crystal display LVP, in
battery discharge test and other applications, set the appropriate LVP, can
effectively prevent battery over discharge, so as not to damage battery) 7.
The load is turned off by default. After power-on, press the ON/SET button to
start or shut down. 8,
all settable parameters can be stored off power.
3.2 Detailed operation 1,
the operation of the potentiometer The
potentiometer is used to adjust the load discharge current, clockwise rotation,
the current value increases, and the counterclockwise rotation current value
decreases. 2, button
operation detailed
3.3 Product display interface
4. Note
4.1 Please read the manual carefully before
using this product! If the module is damaged due to incorrect use, or if the
device is removed without authorization, it will not be returned.4.2 The power supply voltage should be
DC5V, DC power supply, do not use AC power! If the voltage is over voltage, the
module may be burned after power-on;4.3 The voltage at the load input should be
between DC 1.5V and 25V. The current should be below 4A (ZK-FX25) or 5A
(ZK-FX35).4.4 The load input port should not be
short-circuited, otherwise the product will be burnt.4.5 Be careful not to get wet of the
module. Do not short-circuit the components on the board. Do not touch the pins
and pads of the components on the board.4.6
Disclaimer: This product can not be used in medical, life-saving, flammable,
explosive, and other fields and occasions. Our factory will not bear any
responsibility for the consequences